Generator Will Only Run With Choke On

1961 - 1966 F-100 & Larger F-Series Trucks - 1963 F100 223 6cyl only runs with choke on - I have a 1963 F100 223 6cyl that starts hard and only runs with the choke on. Self-diagnostic capability to simplify troubleshooting. com/small-engine/665ez-engine-will-run-full-choke. This web site will explain how I built it. I have a Jonsered GR50 brushcutter/strimmer which will only run on choke. So the generator will not run smoothly unless I have the choke on. Any less choke and it will shut down in about 5-8 seconds. I completely stripped the carb down and cleaned it and it will still only run on choke. Remember never operate your generator in confined spaces especially inside your home. These conditions interfere with normal fuel delivery. I installed a new plug, new gas, filter, pump, checked lines, cleaned carb once. Re: Onan generator only runs on choke If you still have the OEM Facet fuel pump, we found that if it has not run is a while and with its age, the rubber in the diaphrams, there are two small ones in this pump, come apart and get into the carburator. This has worked well for several posters who had small engines that would run, but only on choke: Try SeaFoam in the tank before giving another kick at the screwdrivers Get the Seafoam stuff, and add it to the fuel in the tank at maybe double the ratio stated on the can. Anybody ever have to use a Power Generator to DJ? but i always run my stuff with protection nowonly £10 for a 4 way to explain how the choke control works. Gasoline spilled on hot engine parts could ignite. I had the carb cleaned, plug cleaned, replaced the fuel and I cleaned the spark arrestor. Update: Finally bought a Fluke meter with an "in rush" feature. Without the fridge amperage (listed on fridge) it is impossible to say for sure. Sounds like a vacuum leak. You may have carbon monoxide poisoning. After that, the generator started on the first pull. It will not run except on choke. Unlike other generators, this comes with an electric start. The auto choke modes use a tradition choke valve actuated by an air vane and thermal actuator. Have generator in 82 Rockwood motorhome on chevy chassis. The first person to patent a carburetor for use in a petroleum engine was Siegfried Marcus with his 6 July 1872 patent for a device which mixes fuel with air. Adjusting the electric choke on a Holley four-barrel is simple. Models 30477 & 030477 1) If your generator has the choke control knob on the control pannel, the choke control cable will not attach to this carburetor, which means that the choke control knob on the control pannel will be useless. Honda EX-1000 product reviews by real people like you. Pulled the fuel filter and cleaned it. 5HP Honda GX160. Dry your hands if wet before touching the generator. If you need specific repair instructions related to your model, refer to the manual provided by the manufacturer. I've ran it for about 5 to 10 minutes in the full choke position but every. When the start button is pressed it bypasses the oil pressure cut off circuit and the engine will run only if the button is pressed in. As soon as the choke shutter breaks contact with the casting wall the engine stumbles and dies. fuel filter flushed, tried to run it til hot, no change. Manually operated choke control systems are commonly found on outdoor power equipment. The Onan engine is known to get a Idle jet plugged up from sediment in the carb. I have a 3500 watt champion genny that I use for bowfishing, it will only run on full choke and still only handles a small load. Hello i have a Honda GX160 and the engine will only run on choke if i close it the engine just splutters and thats it. So basically it WILL NOT run without full choke, and even with full choke on I still can't ride the thing because as soon as you give it throttle with full choke on it will stall, I guess it gets flooded with gas. Runs one or two air conditioners with power to spare. Don’t operate your generator (unprotected) in a storm Heavy rain can cause electrical shock and damage to the engine. Page 1 of 2 - Cleaning the fuel system on your Honda Generator - posted in The Casita Club Forum: After getting my Honda 2000ui back together after extracting the runaway spark plug I spoke about in another post recently, my Honda would only run with the choke partially on, alerting me that I probably had some carburetor problems, possibly from old fuel residue, since I hadn't used the. I also always turn the fuel to off and run it till it dies. Tecumseh 5 hp model hssk50 67317m snow king. One cause could be an air leak on the carb, head gasket, crankshaft seal. I am getting a code 1-12 on this which when looked up instructs me to go to the Onan dealer. The carb was cleaned properly and all orfices opened up. The engine here never runs at full speed but produce the needed power. This is the common gas kit with a nail shape choke usually installed on most generators. Roughing it is only fun until you can’t make a cup of coffee or charge your cell phone. There are two different adjustments that can be made: 1) Choke Operation The choke operation (opening and closing) can be adjusted by rotating the choke cap. Ideas on what to do?. Once the generator starts you should move to step 8. ) GEN7000 7000 Watt Generator Manual. What you need to do (depending on how old your snow blower is and long it has been in storage) is turn off the fuel supply and remove the nut that holds the carburetor bowl on (and bowl too). Fuel efficient - runs up to 18 hours on 5. I also always turn the fuel to off and run it till it dies. The other could be a clogged low speed and idle circuit. It actually runs great with no air box, but as soon as the filter is on it runs half power and it needs choke. Both the manual choke system and the manual primer system engines may experience this similar symptom of running only when the fuel mixture is enriched. What I seen was the choke would get blown (sucked) open as the engine cranked. I completely stripped the carb down and cleaned it and it will still only run on choke. Fuel level: Fill gas tank to just below the fill neck so there is room for the gas to expand. Ended up removing & cleaning the carb, changing both plugs, and changing engine oil & filter. Gasoline is extremely flammable, and gasoline vapor can explode. Sits all winter, pull the string and off it goes. Any thoughts will be appreciated. Generator model 580. This way, the only time the choke is actually receiving voltage is when the engine is actually running, not just when the ignition is on. Nice generator, not many hours on it. When I converted my generator on natural gas. Keep the generator dry and do not use in rain or wet conditions. Re: kipor generator hunting / surging, esp at idle The need for choke suggests either an air leak some where or problems with the slow running jet, both of which would cause lean running which is compensated for by using the choke. Possibly the equipment you have plugged into it is drawing more than 5,000 watts. After the engine starts, move engine choke to “run” When the engine has been running for a few moments, you can move the choke back to the “run” position. Over time, the automatic choke can become out of adjustment and will. Topic: Engine will only run with choke. When I turn the choke off it doesn't cut out immediately, it carries on running for a bit before gradually. (Refer to the Generator Components chart to find the location of the Choke Lever. This versatile service tool speeds the troubleshooting process by eliminating guesswork and pinpointing problems. To calculate the generator capacity you need, add the wattage of all the equipment you want to use at the same time (you can find this on the equipment's label or in its manual). The choke is used to provide proper starting mixture when the engine is cold. Keep this owner’s manual handy so that you can refer to it at any time. It may also be some trash inside the fuel tank partially blocking the fuel inlet. Original 1964 Kohler K181 engine on a 1964 864 Wheel Horse. Off and on it will stall or just about stall. I can run 1 refrigerator and charge the solar generator though so I can have quite power at night. So if it will only run choked, even when warmed up, it sounds like too much air is getting into the engine. Tried to run it this year and basically it will only run with the choke on, even when its warmed up. 2 Amps max (=surge or start). If you put the choke on it will stall the engineso you sure you know which is on and which is off. Exceptionally low vibration levels. HRB 215 HONDA Lawnmower (plastic deck type) Wont START Starts then DIES ~ RUNS with CHOKE on only ~ - Duration: 19:46. Generac generator troubleshooting when the engine shuts down during the operation. And it worked fine first start up and ran for about 10 mins just fine. Would still probably work for my fridge and 6,000 btu a/c, but won't run full load, which really bothers me. Choke Rod The choke is used to provide an enriched fuel mixture when starting a cold engine. Fire up the engine on the dead generator and warm it up until it runs smoothly with the choke off: it isn't under load yet, but it will be. I was watching TV and had a light on and a small fan. Note: If the generator has not been run for several months, the carburetor float may be stuck closed and /or the jets and needle valves may be gummed up by old fuel that has turned to varnish. Honda EU2000i The generator at the high speed surges (speeds up, slows down and stops) when the choke is off. With full choke, engine running at rpm specs. Generator was running fine when used last time. Ime they usually get stuck with the choke on since that is the resting position but I've seen cases where the return spring came off or someone massed with it and put it back together wrong and it was stuck with the choke off. Foolishly, I've left this laid-up for around 18 months with the fuel still in it. The shutoffs are intended to reduce. Pressure washer only runs with choke on discussion in the Tool Talk forum at Yesterday's Tractors. Over time, some of the ingredients in the fuel may eva porate, leaving behind a thicker, stickier substance. I have a Jonsered GR50 brushcutter/strimmer which will only run on choke. Stalling Briggs and Stratton, will only run on half choke. It turned out that the carb was loose, allowing air to leak in and dilute the vapors, hence only running with a closed choke. ENGINE ONLY RUNS ON CHOKE This problem is usually common with Briggs and Stratton Vacu-Jet and Pulsa-Jet diaphragm style carburetors. it has ran good since i bought it brand new. Allow the engine to cool if the generator has been in operation. how to clean a generator carburetor. It only used to start with closed choke (air opened). Would this be any sort of clue like it might be running too lean? I know the choke makes it run rich. Any ideas on what the problem is? Thanks!. Restarts when hot with out issue. Description. This makes it great for overnight power. These are the most common Honda generator problems we see. This generator includes six outlets and provides 10,000 starting watts and 8,000 running watts. The Eu2000 will grudgingly run a Skill 77 saw etc, so it, too, has a place, but my EU2000 is the least often used here. California utilities are scrambling to find ways to keep the water running and toilets flushing during Pacific Gas and Electric Co. Guide to Buying 1UQ Manual Choke Carburetor Carb For Champion Power 40030 41302 41311 41331 6000 7000 Watt 6KW 7KW 6000W 7000W Generator are perfect for including character to your room. It used to run, as far as I know it hasn't run in at least a year. The switched wire from the alternator. It will start with choke fully on and then if i back it off to about half way it will run like a champ and i can load it up (tried shop vac and table saw), but if i take the choke to run it stals out. When it is not choked it is starving for fuel runs very rough and the ecco throttle does not work. I found that the idle does run straight and smooth if I put the choke on about half way. The problem is that if you cinch the cap down snugly, the generator will eventually either choke and die or at least sound like it wants to commit suicide. Machine is about 10 to 12 years old. Sounds like a vacuum leak. After 30 days t starts to form varnish that looks like red rust flakes. This will create problems if you need to turn it on again. seems to work fine. I have a Jonsered GR50 brushcutter/strimmer which will only run on choke. Installed carb kit and same problem. Equipped to run on either gasoline or liquid propane, this dual fuel unit can perform anywhere that portable power is needed. And yes i am geting fuel. I had to pull the choke out a bit to get it to run smooth and not "hunt", but it did run all day. As soon as I give it revs the choke automatically disengages & the engine stops straight away. This is the common gas kit with a nail shape choke usually installed on most generators. 1) Set choke a little tighter and retry. Keep this owner’s manual handy so that you can refer to it at any time. It also lacks power and after running for a while will stall. Tried to run it this year and basically it will only run with the choke on, even when its warmed up. I have replace the fuel filter thinking it wasn't getting enough fuel. It is one of the best 1000-watt inverter generators for powering the lights, a television or mobile computer. check for air leaks at the carb with a can of starting fluid. Carberator, along with bowl, jets etc cleanerd, generator gas new. I have taken the muffler off & it was well choked up with coke but after cleaning it's still doing it. I purchased the wheel set and those attached pretty easily, although the generator is quite heavy to move around to attach the wheels. tried another carb & still the same. No codes flash. Then I would close off the fuel valve and run it out. When it was running on Gasoline. I noticed this solenoid mounted on the bottom of the float bowl, I pulled it out and cleaned out the main jet. If in the economy mode it will run for a while >when I push the choke in, but eventually it dies. It is a relatively hard pull on the cord to crank it, so having the battery option makes it easier to start. Grasp the frame firmly to prevent the generator from falling over when pulling the recoil starter. If you run the generator in an area that is confined, or even partly enclosed area, the air you breathe could contain a dangerous amount of exhaust gas. You'll first have to flip the on switch, then apply the choke by turning the lever all the way to the left. It should run excellent with the choke closed. I need to wire an electric choke on my carburetor. I cant understand why the engine runs on full choke, they usually only give a kick and you go to half choke for cold start and then fully open once engine warmed up. Honda Black Max 2600 PSI Pressure Washer. Generator still only starts and then shuts down after 4 seconds. Choke/Open , Eco switch ON my generator "powers down" and idles at a Low RPM like it is suppose to. The effect of this is that the choke can only be fully closed when the throttle is wide open - when the genset starts to run and comes up to speed, the governor will close the throttle which will force the choke to open partway - even though the tab connected to the choke spring may still be calling for full choke. I can spray starting fluid into the intake, choke it, engine will catch on the first pull but won't stay running. I have been lucky so far. Ultimate Predator Generator Reviews You Need To Rely On Portable generators are a great boon to many households and business establishments. Portable Generator Parts Specialists stocking 500,000+ parts for over 800+ brands of portable electricity generators. I have a generator with a briggs 8hp that only ran on full choke. Onan Generator Starts Then Dies: M H Bell: 3-20-08 : My Onan Gen Marquis Gold 5500 series will start then die after about 2 seconds. My generator won't. Any thoughts will be appreciated. It was running same. https://www. Honda Black Max 2600 PSI Pressure Washer. You can try adding a gas preservative to the fuel and see if that helps, otherwise start by removing bowl on carburetor and cleaning. It has got a strange problem. Only use standard unleaded petrol. So basically it WILL NOT run without full choke, and even with full choke on I still can't ride the thing because as soon as you give it throttle with full choke on it will stall, I guess it gets flooded with gas. I was looking at various generator inlet boxes and noticed that there are boxes rated at 30 Amps and 50 Amps. The engine only will run in the "full choke" position -- with the choke knob turned all the way to the right. i turn the choke on to start it and the turn the choke off once it starts. I have a rigid rd8000 generator that is a little older but i cannot seem to get running correctly. Starts on full choke but will stall with choke fully open. I bought a predator generator 2500(honda clone) knowing it will only start and run of full choke. If the chainsaw runs poorly, the fuel filter might be clogged. Guide to Buying 1UQ Manual Choke Carburetor Carb For Champion Power 40030 41302 41311 41331 6000 7000 Watt 6KW 7KW 6000W 7000W Generator are perfect for including character to your room. What you need to do (depending on how old your snow blower is and long it has been in storage) is turn off the fuel supply and remove the nut that holds the carburetor bowl on (and bowl too). Two possibilities, 1 Air leak-carb, head gasket, crankshaft seal. So the generator will not run smoothly unless I have the choke on. The original carb would only run the generator with at least 1/4 choke or more. Instead, it sends extra fuel through the carburetor. Be sure to provide adequate ventilation Operate the generator on a level surface. That’s why I bought a solar. after banging my head against a wall for the last 30 days and living with it fully choked I finally found the problem. While there are a number of reasons why an engine may suddenly develop a "runs only while the fuel is manually enriched situation", the three most common reasons would be:. I purchased the wheel set and those attached pretty easily, although the generator is quite heavy to move around to attach the wheels. An engine runs the generator. I noticed on your model that the engine has a fuel pump and the fuel tank is in the rear of the tractor. Champion was running like a champion in two pulls! Smooth even running, no surges, and choke was fully off. The Poulan tree trimmer runs but only with the choke set at half open. You should also check that the choke is standing completely upright when the engine has been running for a while - if it's leaning over at all then it will cause flooding. You can try adding a gas preservative to the fuel and see if that helps, otherwise start by removing bowl on carburetor and cleaning. Gasoline is extremely flammable, and gasoline vapor can explode. Runs sometimes. ( inline fuel filters are only a few bucks, if your not sure just replace them ) you might also have to clean the carb, over time varnish will build up this is common if the generator is not run on a regular basis, and allowed to sit full of fuel, but for the most part can be avoided by disconnecting the load, and turning off the fuel valve and. I gased it up and was able to start it with the full choke on. The generator is out of gas or is low on gas. No fear of frying the choke coil. No codes flash. I have noted other postings about similar problems where answers resorted to cleaning out the bowl and flushing with carburetor cleaner but this has not resolved the issue. Generator will start and run with the choke on but stalls when you push the choke off. It also used to start with half choke. The generator will start and appears to run at speed with the choke on but it dies when I move it to run. Generator GP7500e model # 0059432 would not start, then started and run on 2020RPM the throttle full open, voltage 85V/180V ,when I removed air filters RPM went up to 2600RPM. If you need specific repair instructions related to your model, refer to the manual provided by the manufacturer. To calculate the generator capacity you need, add the wattage of all the equipment you want to use at the same time (you can find this on the equipment's label or in its manual). Why does the choke help an engine start when it is cold? I know that the choke restricts the air flow and thus makes the mixture of air/gas entering the engine more concentrated with fuel, but why would that make it easier for the engine to start on a cold day? Shouldn't the engine be easiest to. Ime they usually get stuck with the choke on since that is the resting position but I've seen cases where the return spring came off or someone massed with it and put it back together wrong and it was stuck with the choke off. I cant understand why the engine runs on full choke, they usually only give a kick and you go to half choke for cold start and then fully open once engine warmed up. The engine here never runs at full speed but produce the needed power.   It ain’t happening. I purchased a new predator 212212 for my sons go kart build and can't get it to run without the choke on slightly. 5A •Only connect this generator to. "I have a Honda EU3000is Generator. There are two different adjustments that can be made: 1) Choke Operation The choke operation (opening and closing) can be adjusted by rotating the choke cap. Setup was a bit difficult. Have a 1997 Toro Z master 222 with a Kohler Cv730-0027 with a 25 horse power engine in it that would only run on full choke I found the problem it's fixed. The engine started on the first pull with the new carb, but will only run on full choke. Still only runs at half choke, and dies when I load it with the same tools (near max capacity) as when I first bought it. Seems to work a lot of times for me and its only $7 or $8 a can. Tecumseh 5 hp model hssk50 67317m snow king. I'm finishing up a go kart and have a problem with my engine. Lawnmower Repair and Service Maintenance Tips 41,928 views. I have replace the fuel filter thinking it wasn't getting enough fuel. Machine is about 10 to 12 years old. It may also be some trash inside the fuel tank partially blocking the fuel inlet. 5500W DeVilbiss Generator (I think now they are owned by Porter Cable) 10 HP Tecumseh HM100 Engine also says 159409P on the tag I'm trying to get it running for someone. Honda power washer only runs in choke will not run with choke off It is starving for fuel. Runs smoothly with choke on, with or without air filter (it is clean and new). The rough operation seems to be only during cold weather operation of the duty cycle. Honda engines today boast of a manual choke that is specially inserted into the throttle control and cable. Makes starting it kinda hard. Guide to Buying 1UQ Manual Choke Carburetor Carb For Champion Power 40030 41302 41311 41331 6000 7000 Watt 6KW 7KW 6000W 7000W Generator are perfect for including character to your room. Carb was taken apart, cleaned and re-adjusted. Re: Onan generator only runs on choke If you still have the OEM Facet fuel pump, we found that if it has not run is a while and with its age, the rubber in the diaphrams, there are two small ones in this pump, come apart and get into the carburator. We have gathered our favorite styles with tips for how to place them and where to place them. It used to run, as far as I know it hasn't run in at least a year. Since the engine needs air to run choking the air supply will also kill the engine. An active harmonic filter cannot be used to correct harmonics from single-phase harmonic sources. It need to autostart when the batteries get low, but with the choke having to be set manually, its not possible. I bought this in 2012 and have test run it. horizontal engine. Hi, I've got a cheap little generator that I picked up for twenty quid. Machine is about 10 to 12 years old. I purchased a new predator 212212 for my sons go kart build and can't get it to run without the choke on slightly. But then if you put full choke on again it would idle fine (fast idle on full choke). ENGINE ONLY RUNS ON CHOKE This problem is usually common with Briggs and Stratton Vacu-Jet and Pulsa-Jet diaphragm style carburetors. The generator is out of gas or is low on gas. It will only run when fully choked. I have cleaned the carburetor and the same symptoms occur. 5 hp Briggs and Stratton motor on it. It actually runs great with no air box, but as soon as the filter is on it runs half power and it needs choke. Seems to work a lot of times for me and its only $7 or $8 a can. ENGINE ONLY RUNS ON CHOKE This problem is usually common with Briggs and Stratton Vacu-Jet and Pulsa-Jet diaphragm style carburetors. I was looking at various generator inlet boxes and noticed that there are boxes rated at 30 Amps and 50 Amps. Its 30 degrees outside. At this point, you can throw off the choke and you should hear it rev up. The jet has small pin hole orifices and once plugged up you will no longer be able to idle smooth and most likely need to use the choke to keep it running smooth. The 50 Amp boxes seem to be about twice as. Thank you. Then fire up the borrowed generator. all of that didn't really matter because I swapped carbs with my pressurs washer and the generator ran exactly the same. If the engine hesitates, pull the choke control out until the engine regains its momentum, then push the choke control in again. com/small-engine/665ez-engine-will-run-full-choke. When you push the choke knob in, the choke plate in the carb should be wide open, allowing air into the carb. Elect fuel pump was checked for pressure. Traditional generators make so much noise. • The generator is a potential source of electrical shock if not kept dry. I removed the float bowl. I was watching TV and had a light on and a small fan. That’s why I bought a solar. com Tecumseh 5 hp model hssk50 67317m snow king. I can spray starting fluid into the intake, choke it, engine will catch on the first pull but won't stay running. If it is stuck (mechanically or electrcially) partially closed could make it hard to start, allow it to run fine and then shut down when it warms up and it would be hard to restart because it would have choked down. Re: Generac 4000xl only runs DECENT on half choke Since you ran vinegar thru it. Holding the primer button in for a longer period of time can cause engine flooding. Check out Expert's recommended alternatives for another top portable generators gas generator. The Generac XG8000E - 8000 Watt Electric Start Portable Generator 5747 has been discontinued. It need to autostart when the batteries get low, but with the choke having to be set manually, its not possible. It actually runs great with no air box, but as soon as the filter is on it runs half power and it needs choke. Ime they usually get stuck with the choke on since that is the resting position but I've seen cases where the return spring came off or someone massed with it and put it back together wrong and it was stuck with the choke off. No fear of frying the choke coil. I am running my generator on natural gas but I always need to choke the gas kit every time. Is this a common. I think I messed up my Champion generator. One carb may fit several applications. This video shows the repair of an Older Honda EX1000 Generator. I think I was the only one in the neighborhood with power. Onan Generator Model Emerald Plus Genset 4000 model#4BGEFA26100N Starts up but will only stay running if I Hold electronic choke in closed position with manual vaccum hose removed from carburetor base. There are two different adjustments that can be made: 1) Choke Operation The choke operation (opening and closing) can be adjusted by rotating the choke cap. I put fresh fuel in it (Aspen) and it started fine, but it only runs on choke. n Operate in a well-ventilated, well-lit area isolated. 1) Set choke a little tighter and retry. as I don't wanted to tap into my oilsender, I used a wire that runs nearby. The generator will start and appears to run at speed with the choke on but it dies when I move it to run. The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. But recently when i turn the choke off the engine will go up down up down up down. Over time, fuel degrades, and since generators by their very nature are used only occasionally, it is not unusual for the fuel to degrade to the point that the generator will not start. When I turn the choke off it doesn't cut out immediately, it carries on running for a bit before gradually. Gasoline is extremely flammable, and gasoline vapor can explode. 7) then put on half choke position and pull several times till starts, moving choke to OFF or RUN position once it has run a bit and then starts to run rough or smoky, which means it is getting too much gas. I bought a used Craftsman 3500 watt generator at a local pawn shop. It turned out that the carb was loose, allowing air to leak in and dilute the vapors, hence only running with a closed choke. By the way, it fires up and shuts down within two seconds. Thank you rotti1968 for the answer! I have had the carb off a couple of times before and thought I cleaned it up very well, but I did not know to remove the jet. Hi, my voltmeter stopped working and the battery won't charge is it more than likely my generator/altenator, also my ih 782 will only run with the choke all the way on, and has trouble starting too, could it be the fuel pump?. Honda Black Max 2600 PSI Pressure Washer. Be ready for anything with the DuroMax XP10000EH generator. Perfect for camping and running household appliances during power outages, this generator features an engine runtime of 8 hours at 50% with just a common, 20 lb. Any help much appreciated. This versatile service tool speeds the troubleshooting process by eliminating guesswork and pinpointing problems. Start the engine, and feather the choke so as to keep her running. The idea of the electric choke is to slowly open the choke as the engine warms. What about with a generator? No stator wire so where is the best place to hook an electric choke and hopefully only get current when the engine is running?. If your generator won't start there is a simple test you can do to see if it's fuel related. Tecumseh 5 hp model hssk50 67317m snow king. I cleaned the air filter, the spark plug and the filter on the exhaust. This owner’s manual is considered a permanent part of the generator and should remain with the generator if resold. I want to be prepared for storms this winter. It also lacks power and after running for a while will stall. Generator was running fine when used last time. I've pulled the idle speed jet and cleaned it. The choke level should always be closed when starting a generator and open when the generator is running. Re: Honda GX140 will only run with choke on « Reply #4 on: September 21, 2010, 12:48 » Re reading your post Gwiz about the jet cleaning I note I removed what I throught was the jet, it was blocked solid, but I did not clean out the other brass bit that was left in the carb. Has a Kawasaki FA130D motor on it, clean changed oil, clean air filter, cleaned spark plug. Machine is about 10 to 12 years old. detector when running the generator. Turn the choke lever back to the “RUN” position. Nice generator, not many hours on it. 5A •Only connect this generator to. After a minute or two it would run normal, or close to it with no choke. When the engine has started, it may be necessary to adjust the RPM. I already changed the gas I have good spark at the plug and i cleaned the carb. I found that the idle does run straight and smooth if I put the choke on about half way. When I turn the choke off it doesn't cut out immediately, it carries on running for a bit before gradually. Easy to transport over any terrain, from the neck of the woods to the downtown jobsite, the XP10000EH generator will keep you going. air filter have gas/oil deposit. As far as I know the only thing the choke does it is "choke down" the air intake, so what the heck? Any ideas on why this is happening? Thanks. Had a power outage from a bad storm and a couple of neighbors heard my generator running that night. this generator is only about a year old. Two possibilities, 1 Air leak-carb, head gasket, crankshaft seal. Drop float bowl, with the use of a very, very small drill bit, clean out the pick up metering jet. On mine the only way to look through that opening is to remove the generator, then remove the entire cover.